AXK150190 bearing: complete specifications & equivalents

The AXK150190 is a ISO 3031 radial bearing sized 150 x 190 x 5 mm (bore x OD x width). Verify dimensions against the official catalog before ordering.

Bearing dimension schematic Front view shows outer diameter D and bore d; side section shows width B. D = 190 mm d = 150 B = 5 mm side section front view
Principal dimensions: bore d 150 mm, outer diameter D 190 mm, width B 5 mm. Schematic, not to scale.

Specification table

ParameterValue
Brand SKF
Bore diameter d 150 mm
Outer diameter D 190 mm
Width B 5 mm
Material GCr15
Seal / shield open
Internal clearance CN
Tolerance class P0
Cage steel
Basic dynamic load rating C 120 kN
Basic static load rating C0 950 kN
Fatigue load limit Pu 102 kN
Reference speed (thermal) 1000 rpm
Limiting speed (mechanical) 2000 rpm
Operating temperature -40 to +120 °C
Mass 232 g
Manufacturer designation AXK 150190
Standard ISO 3031
Catalog version SKF PUB BU/P1 17000/1 EN (Oct 2018), ch. 12.1 needle roller and cage thrust assemblies
Last verified 2026-09-27

Source: catalog reference (SKF PUB BU/P1 17000/1 EN (Oct 2018), ch. 12.1 needle roller and cage thrust assemblies) · extracted 2026-09-27

Parameters extracted from the official SKF Rolling Bearings catalogue (SKF PUB BU/P1 17000/1 EN (Oct 2018), ch. 12.1 needle roller and cage thrust assemblies); SKF® and SKF Explorer® are trademarks of AB SKF, used here for identification only — mpnbase is not an authorized SKF distributor. Boundary dimensions are ISO 15 interchangeable; current production values may differ, verify at skf.com.

Dimensions in inches & AXK-series range

Bore d5.906 in
Outer diameter D7.48 in
Width B0.197 in
ISO bore code90
Radial section height (D−d)/220 mm
Smallest bore in AXK-series4 mm
Largest outer diameter in AXK-series200 mm
Width range across AXK-series2–5 mm
Bore position in AXK-series (smallest first)29 of 30
Bore above smallest AXK-series size146 mm

Cross references & equivalents

Equivalent modelBrandMatch levelNote
AXK150190 ISO 15 full
Dimensions and internal design equivalent — standard interchange.
ISO 15 boundary-dimension envelope; standard interchange — confirm clearance class and precision with the supplier.

Interchange levels: full standard interchange · partial verify parameters · verify manual confirmation required. Links resolve to the equivalent model's specification page where available.

How the AXK150190 model number is decoded

AXK 150190 gives thrust capacity in the height of a shim: 150 mm inner track, 190 mm outer track, only 5 mm thick, with needles held by the stamped steel cage for one-direction axial load. SKF prints the AXK sizes as adjacent figures, so 150/190 reads 150 then 190 mm; the assembly has no washers of its own — order AS/LS washers or harden the mating faces. The thin section tolerates no misalignment: keep the mating faces parallel, and use the AXW spigot-flanged execution where a one-piece, housing-centred cage-plus-washer unit simplifies assembly. Selection arithmetic: C 120 kN against C0 950 kN gives a C0/C ratio of 7.92 — thrust bearings are chosen on static rating and F_a/C0 more often than on L10 life. Grease both faces before assembly so the needles stay in their pockets, especially for the 5 mm thin set; after fitting, rotate slowly and confirm the cage does not catch on the shoulder edges.

Typical equipment & failure modes

Common applications

  • automotive manual and automatic transmission thrust positions
  • torque converter and clutch release assemblies in passenger cars
  • small gearbox gears that need a 2 mm thrust shim between a shaft and face
  • light turntables, index plates and office-machine pivots

Known failure patterns

  • instant raceway scoring when the assembly runs against a face below 58 HRC or with a rough finish
  • roller skidding and raceway glazing once the thrust falls below the catalogue minimum axial load (factor A)
  • grease churning and overheating when a high-speed thrust position is over-packed
  • condensation pitting in machines that run intermittently in humid environments
  • edge loading across the needle crowns when the mating faces are not square to the shaft

Selection pitfalls — read before you substitute

  • Above 110 mm the large AXK sets (150–190 mm) are assembled standing up in vertical gearboxes — retain the cage or it walks off its track before the first bolt is torqued.
  • The 120 kN rating is real only at 58–64 HRC face hardness; visual inspection cannot tell a 45 HRC washer from a 60 HRC one — order certified washers.
  • Do not expect misalignment tolerance: a 5 mm rigid needle set edge-loads if the faces tilt even a fraction of a degree — use a spherical or AXW solution where the seat cannot be kept parallel.
  • The AXK code supplies no washers: AXK 150190 arrives as the needle cage only, and a "bearing failure" on hard-faced tracks is usually a missing-AS-washer failure at ordering time.
  • Match washers by the exact 150–190 mm track — a washer sized to the shaft alone leaves the needles overrunning its edge, which shears the cage.
  • The 120/950 kN ratings and 232 g mass are SKF catalogue values transcribed from ch. 12.1 of PUB BU/P1 17000 (PDF table page 910); mounting data — Ea/Eb raceway diameters and the minimum load factor A — appears in the running text because the structured record carries the boundary envelope only.

Frequently asked questions

Which dimensions does the AXK 150190 have?

A AXK 150190 measures 150 mm bore × 190 mm outside diameter × 5 mm width (5.906 × 7.48 × 0.197 in). From SKF catalogue PUB BU/P1 17000: dynamic C 120 kN, static C0 950 kN, fatigue limit Pu 102 kN, reference speed 1,000 r/min, limiting speed 2,000 r/min, mass about 232 g. The contact band runs Ea 156–Eb 187 mm; hardened washers or 58–64 HRC faces are required.

What does AXK 150/190 mean?

A needle roller and cage thrust assembly (ISO 3031) for a 150 mm inner track and 190 mm outer track, 5 mm thick; one-direction axial load, washers ordered separately.

What is the difference between AXK and AXW?

AXW pairs the AXK needle set with a washer carrying an integral centring spigot that locates in a housing register, keeping cage and washer concentric as one part; AXK is the bare cage-and-needle set needing two separate washers. The AXW still needs a separate LS/AS washer or hardened face on the opposite side.

Does the AXK 150190 tolerate misalignment?

No — the 5 mm rigid needle set edge-loads on tilted faces. Keep the shaft and housing faces parallel, or choose the self-aligning roller thrust families.

Reviewed & verified by the MPN Base engineering desk against source catalog SKF PUB BU/P1 17000/1 EN (Oct 2018), ch. 12.1 needle roller and cage thrust assemblies on 2026-09-27. Read our editorial & correction policy.